Hello Friends
Please go through my below study where the scenario is completely in MTO / VC , and users wants the sales order specification to be fetched into inspection result recording.Please share your experience, if ever had countered with such an issue .
I have an MIC - NEWH_C , which is assigned to a class characteristic U_C_PCT . The MIC has same properties as U_C_PCT. The Lower and upper value derived from the class characteristics which id 0.0 to 100.00. The MIC also assigned in the inspection plan.
I have already activated the enhancement-QMCF0001 and applied the code fully from the SAP Note-119708.
In the table ZQMCF (Table made as per reference in the note 119708) i have arranged the characteristics (U_C_*) in the following manner.
PARENTCHAR | LOWERCHAR | UPPERCHAR |
U_C_PCT | U_C_PCT_EXT_MIN | U_C_PCT_EXT_MAX |
All the above three characteristics have same properties (Char Length , Decimal Places and UOM). The three characteristics are already assigned to a 300 class.
During making a sales order the values are maintained for all of three characteristics as follow.
U_C_PCT = Left Blank
U_C_PCT_EXT_MIN = 0.12
U_C_PCT_EXT_MAX = 0.22
Now Production order has been created with reference to the above sales order and after production confirmation inspection lot also generated.
In the result recording screen of Inspection Lot, against the MIC, NEWH_C the specification was supposed to be shown as 0.12 ....0.23 % , but instead it shows the specification as 0 to 100 % , which is derived from the original MIC.
I have tried all effort of updating MICs and Class Characteristics , but the problem not resolved yet.
Please share your views.
Regards
DD