Requirement in equipment calibration
Dear All, I have some requirement in the equipement calibration as given below. 1) Next call date should be less than 1 day for the next call . Means if my cycle time is 1 month, and start of cycle is...
View ArticleQM notification workflow with multiple scenarios
Dear experts, I got a request from business to work out a workflow solution for quality notifications based upon multiple business scenarios. Our company has several business/product lines and they...
View ArticleInspection lot created at GR on PO
Hi QM Experts, My customer uses Inspection Lot for production.We use a copy of 04 Inspection Type. Inspection lots are created at production order release. When activating QM I encoutered the...
View ArticleTransfer single results from results recording to batch characteristic
Hi all, I've a question. Is it possible to transfer multiple single results from results recording to a batch? It should only be qualitative results. The problem is as follows. We have a SAP - LIMS...
View ArticleSAP note for UD reversal for mvt 322 with inspection type '01'
What is SAP note n Which note use for UD reverse for mvt 322 with '01' inspection type? ....plz help me
View ArticleCutting the batch where-used list and start batch history from scratch
Dear community When we print a certificate, the specifications and their results recorded come from the inspection lot of the batch. This inspection lot takes information from the inspection plan...
View ArticleCOST OF QM notification in QM Order
Hi All, I am creating QM Order with respect to QM notification by giving defect but I am unable to get cost of notification in QM order in fact I am unable to give cost in QM notification itself,...
View ArticleQM-Report
Hi All, I am stuck in one of the report development, where in i need to develop a report of finished goods i.e. defect wise report of 2 W/C's in a single reportEx: 1st W/C- inspection lot generated and...
View ArticleSAP QM UD reversal for 08 inspection type
Dear ExpertsI need clarification on following pointswe have uploaded stock in last financial year dt 01.06.2014 and we did stock transfer in 15.04.2015 in current year. we have activated 08 inspection...
View ArticleHow to assign email ids to Followup mail in UD
Hi all,Is there any settings to assign mail ids for MAIL2 function module using for Followup action in UD section.I have maintain all the IMG settings like assign MAIL2 in followup action field and for...
View ArticleIW51 - Service notification after save action
Hi Experts, we are working on IW51 enhancement on which we encounter some difficulties. Once we save the service notificiation we create an item on it (QMFE table).In that item we have cliassification...
View ArticleProblem related to SAP QM/ Result recording
There is an inspection plan for LDO. An MIC called 'Density' is attached to the inspection plan. This is a quantitative MIC and it has lower and upper specifications attached to the...
View ArticleECR/ECO problem with automated transactions
Hi Friends, I have problem with automated close of ECR. Description:I have change number with one object - Inspection Plan.In CC32 when "Incorrect Change" is set and I click "Erro Corrected" - nothink...
View ArticleSAP QM Inprocess Inspection for a specific Process order type
Dear All, There is a requirement. As no QM type is maintained for FG material in a plant. Now the requirement is there is a specific order type for which Inprocess Inspection is to be activated for...
View ArticleQS42 Long text different view
Dear Gurus, we have the following problem :When we run t-code QS42 in order to create a new catalog (2) we are not able to insert a own long text for each value catalog. In the screen below you can see...
View ArticleSPC Chart
Hi All, I am to whether i am performing the correct steps for SPC chart, if i am woring please guide me for the sameFor a MIC, i have maintained SPC tick mark, Sampling procedure tick, single result...
View Articleinconsistency between MIGO document serial number and stock
There is a inconsistency between MIGO document serial number and stockavailable serial number but we could not understand how thisinconsistency occurred. Now we are not able to post the UD for this...
View ArticleQM Results recording during Operations confirmations
Hello Experts I have just come across a requirement and would be grateful if someone can help me out in this regard 1. Industry : Aerospace and Defense2. Products : Electronics Cards Assembly...
View ArticleIn IQC raw material not good ,vendor hope scrap on site,how and where to...
Hi,Guru,I met a question ,that is ,in IQC (in coming quality control for raw material ) ,the 6 raw material in 10 is defect ,vendor hope scrap it on site at once. My question is how to deal with the 6...
View ArticleQuality Notification creation - how do I communicate this to a diverse group?
Hello Experts;We have a requirement for Quality Notification type Q2 to be sent to multiple internal SAP contacts throughout the organization on creation. If a defect is found / reported at a location...
View Article